Debug Mode ON
ContentID: 19774
Template: product.aspx

Kingfisher Plus

Powerful, Resilient, Modular and Secure monitoring and automation platform.

KingfisherPlus_RGB_OverWhite.png

HIGHLY RESILIENT AND SECURE MODULAR AUTOMATION

Kingfisher Plus from Ovarro is a highly resilient and secure automation platform for critical and demanding SCADA applications.

Features & Benefits At A Glance
Ovarro_Icons_F&B_NoTitles_Colour_RGB_Connected.svg

Multiple redundancies (CPU, Power, Comms)

Ovarro_Icons_F&B_NoTitles_Colour_RGB_Modular.svg

Modular System

Ovarro_Icons_F&B_NoTitles_Colour_RGB_Tablet.svg

OLED & LED display

Ovarro_Icons_F&B_NoTitles_Colour_RGB_Performance.svg

SD Cloning

Ovarro_Icons_F&B_NoTitles_Colour_RGB_Tech Spec.svg

Rugged & Robust for the harshest environments

Multiple Redundancies

Reducing risk of systems failure, Kingfisher RTUs provide redundant processor, power supply and communications modules.

Processor modules support CPU redundancy; switchover from the primary to the backup processor will occur upon failure of I/O module scan, communications failure on selected ports, Toolbox command, or a ladder logic command.

All modules allow 'Hot swap' of any card which removes the need to restart the RTU which helps to improve operational efficiency by saving engineering time.

Kingfisher CP35 RTU shown as a complete rack.
Single Kingfisher Plus RTU module
Programming

Kingfisher RTUs provide an open, programmable automation environment based on ISaGRAF version 6.5.

Kingfisher’s configuration and programme development tool Toolbox Plus supports all 5 IEC 61131-3 languages and a rich library pre-engineered function blocks provides built-in programming shortcuts, which project engineers find invaluable.

Modular system with advanced processing

An advanced high-performance processor seamlessly interfaces with intelligent communications and I/O modules to exceed the needs of the most demanding remote monitoring and control applications.

The modular system allows you to install only what you need so it grows as your network does, helping you to manage your CAPEX & OPEX spend.

Discover how Kingfisher RTUs have been trusted by a major urban gas enterprise in Asia for the monitoring and control of metered off takes, gas storage, CNG stations and pressure regulation stations.

 

Micro photo of part of a Kingfisher Plus modular RTU
Telemetry software | Data processing | Real-time
Rugged & Robust for the harshest environments
  • Wide temp range (-40C to +85C)
  • Up to 5000V isolation
  • Hot swap any card

Read the case Study

 

OLED & LED Display

Save engineering time thanks to the OLED & LED displays on the Kingfisher Plus. It gives users direct access to diagnostics to identify issues faster, supporting on-site maintenance and configuration without any tools.

Find a distributor

OLED and LED displays on Kingfisher Plus RTU

Variant

CP-12
CP-35
ContentPartIDDateCreatedDeletedContentIDContentPartTypeIDRankRank2Rank3TitleSummaryDescriptionHTMLMediaIDMediaAltDescriptionLinkTagTag2Tag3Tag4Date1Date2FormID
2244629/06/2020 17:48:221621920FLASH RAM 512kB 0  CP-12Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
10729701/09/2020 12:02:4816211120FLASH RAM 2GB eMMC (expandable) 0  CP-35Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
2246529/06/2020 17:48:221621920CPU 40MHz x86 0  CP-12Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
10731801/09/2020 12:37:521621920CPU 1GHz ARM9 0  CP-35Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
2244529/06/2020 17:48:2216211020Memory 512kB 0  CP-12Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
10729601/09/2020 11:58:3116211021Memory 256MB (512MB ECC) 0  CP-35Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
2244829/06/2020 17:48:2216211320Clone System to SD Card No 0  CP-12Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
10729901/09/2020 12:07:4916211320Clone System to SD Card Automatic Cloning 0  CP-35Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
10730001/09/2020 12:09:2116211420Battery Backup >20 years 0  CP-35Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
2244929/06/2020 17:48:2216211420Battery Backup >7 years 0  CP-12Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
2245029/06/2020 17:48:2216211520Event Logging 20,000 0  CP-12Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
10730101/09/2020 12:10:3416211520Event Logging 100,000 events (up to 10 DNP3 masters) 0  CP-35Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
10730201/09/2020 12:11:5016211620Configuration Software ToolboxPLUS 0  CP-35Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
2245129/06/2020 17:48:2216211620Configuration Software Toolbox32 0  CP-12Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
2245229/06/2020 17:48:2216211720Programming Languages Ladder Logic 0  CP-12Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
10730301/09/2020 12:12:4716211720Programming Languages IEC61131-3, All 5 languages, with user defined function blocks 0  CP-35Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
10730401/09/2020 12:17:4816212020Load Configuration from USB Stick No 0  CP-12Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
2247529/06/2020 17:49:0516212020Load Configuration from USB Stick Yes 0  CP-35Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
10730501/09/2020 12:20:0416212120Update Firmware from USB Stick Yes 0  CP-35Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
2245429/06/2020 17:48:2216212120Update Firmware from USB Stick No 0  CP-12Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
2245529/06/2020 17:48:2216212220Save Diagnostics to USB Stick No 0  CP-12Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
10730601/09/2020 12:21:2516212220Save Diagnostics to USB Stick Yes 0  CP-35Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
10730701/09/2020 12:22:2216212320Password Protected Menu System On CPU via OLED Display 0  CP-35Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
2245629/06/2020 17:48:2216212320Password Protected Menu System No 0  CP-12Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
2245729/06/2020 17:48:2216212420Configurations stored in FLASH 1 0  CP-12Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
10730801/09/2020 12:23:2016212420Configurations stored in FLASH 4 + Factory default 0  CP-35Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
10730901/09/2020 12:24:2116212520Firmware stored in FLASH 4 + Factory default 0  CP-35Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
2245829/06/2020 17:48:2216212520Firmware stored in FLASH 1 0  CP-12Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
2245929/06/2020 17:48:2216212620Security Port security 0  CP-12Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
10731001/09/2020 12:25:3816212620Security Role based access, IP white listing, secure webserver, selective lockdown of features, Audit log 0  CP-35Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
10731101/09/2020 12:28:0916212720Protocols Available with standard firmware at no additional cost 0  CP-35Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
2246029/06/2020 17:48:2216212720Protocols Available as drivers at no additional cost 0  CP-12Process Control Unit  01/01/0001 00:00:0001/01/0001 00:00:000
2246129/06/2020 17:48:2216212830Total Ports / RTU Up to 16 0  CP-12Communications supported  01/01/0001 00:00:0001/01/0001 00:00:000
10731201/09/2020 12:29:3316212830Total Ports / RTU Over 20 0  CP-35Communications supported  01/01/0001 00:00:0001/01/0001 00:00:000
2246229/06/2020 17:48:2216213340Option Cards CP-12 & MC-12 = 1 × RS232/RS485 serial port, 2 × option card slots 0  CP-12Option Cards  01/01/0001 00:00:0001/01/0001 00:00:000
10731301/09/2020 12:30:3416213340Option Cards CP-35 & MC-35 = 2 x RS232/RS485 serial ports, 1 x USB, 1 x Ethernet, 2 x option card slots 0  CP-35Option Cards  01/01/0001 00:00:0001/01/0001 00:00:000
2248629/06/2020 17:49:0516213850CPU modules OLED 0  CP-35Diagnostics  01/01/0001 00:00:0001/01/0001 00:00:000
10731601/09/2020 12:35:2316213850CPU modules LED 0  CP-12Diagnostics  01/01/0001 00:00:0001/01/0001 00:00:000
10731701/09/2020 12:36:4716213950Power supply modules LEDs 0  CP-12Diagnostics  01/01/0001 00:00:0001/01/0001 00:00:000
2248729/06/2020 17:49:0516213950Power supply modules OLED 0  CP-35Diagnostics  01/01/0001 00:00:0001/01/0001 00:00:000

Inputs and outputs

Inputs and outputs

1008

Inputs and Outputs

Maximum I/O points

Up to 4 x 2, 4, 6 or 12 slots

Backplanes

Plus 4 × 4 slots per RTU

I/O configuration

Automatic/manual

Backplane sizes

2 / 4 / 6 / 12 slots

Removable I/O connectors

Yes, with locking screw for security

Digital modules

Max. 16 inputs or 16 outputs/module

Analog modules

Max. 8 inputs or 4 outputs/module

Process Control Unit

FLASH RAM

512kB
CP-12

CPU

40MHz x86
CP-12

CPU

1GHz ARM9
CP-35

Memory

512kB
CP-12

Memory

256MB (512MB ECC)
CP-35

FLASH RAM

2GB eMMC (expandable)
CP-35

Micro SD Card

Up to 32GB
CP-35

Micro SD Card

No
CP-12

Clone System to SD Card

No
CP-12

Clone System to SD Card

Automatic Cloning
CP-35

Battery Backup

>20 years
CP-35

Battery Backup

>7 years
CP-12

Event Logging

20,000
CP-12

Event Logging

100,000 events (up to 10 DNP3 masters)
CP-35

Configuration Software

ToolboxPLUS
CP-35

Configuration Software

Toolbox32
CP-12

Programming Languages

Ladder Logic
CP-12

Programming Languages

IEC61131-3, All 5 languages, with user defined function blocks
CP-35

Send Configuration via direct cable

Serial or Ethernet

Send Configuration remotely

Yes

Load Configuration from USB Stick

No
CP-12

Load Configuration from USB Stick

Yes
CP-35

Update Firmware from USB Stick

Yes
CP-35

Update Firmware from USB Stick

No
CP-12

Save Diagnostics to USB Stick

No
CP-12

Save Diagnostics to USB Stick

Yes
CP-35

Password Protected Menu System

On CPU via OLED Display
CP-35

Password Protected Menu System

No
CP-12

Configurations stored in FLASH

1
CP-12

Configurations stored in FLASH

4 + Factory default
CP-35

Firmware stored in FLASH

4 + Factory default
CP-35

Firmware stored in FLASH

1
CP-12

Security

Port security
CP-12

Security

Role based access, IP white listing, secure webserver, selective lockdown of features, Audit log
CP-35

Protocols

Available with standard firmware at no additional cost
CP-35

Protocols

Available as drivers at no additional cost
CP-12

Communications supported

Total Ports / RTU

Up to 16
CP-12

Total Ports / RTU

Over 20
CP-35

Master/slave

Yes

Peer-to-peer

Yes

Redundant/Fallback pathways

Yes

Protocols

Serial and IP versions of Modbus, DNP3 and Kingfisher; IEC60870-5-101 & 104, SNMP, HTTP, HTTPS and SSH with more available on request

Option Cards

Option Cards

CP-12 & MC-12 = 1 × RS232/RS485 serial port, 2 × option card slots
CP-12

Option Cards

CP-35 & MC-35 = 2 x RS232/RS485 serial ports, 1 x USB, 1 x Ethernet, 2 x option card slots
CP-35

Optional cards available

A4 - Ethernet fibre, T4 - Copper Ethernet, H - HART interface, I - Serial copper, I2 - Dual serial copper, L - Private line

Diagnostics

Pre-programmed

Yes
CP-12

Pre-programmed

n/a
CP-35

I/O modules

LEDs
CP-12

I/O modules

OLED
CP-35

CPU modules

OLED
CP-35

CPU modules

LED
CP-12

Power supply modules

LEDs
CP-12

Power supply modules

OLED
CP-35

Report via network

Yes

Software

Yes

Communications analyser

Yes

Service Report

Yes

Power

AC supply

100 to 240 VAC

DC supply

20 to 60 VDC or 96 to 300 VDC

Solar supply

10.5-16..0 VDC

Power down modes

Yes

Battery backup

Yes

Battery size

Various

Battery charging option

Yes, with Thermal compensation

Environmental

Operational temperature

-40° to 85°C (see hardware manual for exceptions)

Storage temperature

-40° to 85°C

Humidity

5% to 98% RH non-condensing

Redundancy Levels

CPUs / RTU

2

Power supplies / rack

2
Download Specification Sheet
Kingfisher Plus Brochure
Beijing City Gas Group Trust the Kingfisher RTU

Locate Your Distributor

Click below to search for your local distributor

Make an enquiry

Need more information? Don't hesitate to get in touch